ACL Staticide GL12NI-S ESD Nitrile Gloves, Small, 12-Inch, Case of 500
ACL Staticide GL12NI-S ESD Nitrile Gloves, Small, 12-Inch, Case of 500
ACL Staticide GL12NI-S ESD nitrile gloves combine latex-free, powder-free contamination control with the inherently antistatic, low-tribocharging properties of nitrile. This Small, 12-inch glove is designed for handling sensitive components in electrostatic protected areas and controlled environments. The longer format provides additional wrist coverage compared with the 9-inch version.
Sold by the case: one case contains 500 individual gloves, supplied as five packs of 100. The listed price is for one case, not one pack or one glove. Quantity is gloves, not pairs.
Best Uses / Applications
- Electrostatic protected areas and other ESD-sensitive work areas.
- Controlled critical environments and coordinate measuring machine (CMM) rooms.
- Assembly and packaging where skin oils and handling contamination are concerns.
- Integrated circuit and disk drive manufacturing.
- Defense, avionics, and automotive component handling.
- Tasks requiring a Small fit with longer wrist coverage.
Key Features
- Latex-free, powder-free nitrile construction.
- Manufactured without plasticizers or silicone.
- ACL lists an accelerant-free formulation.
- Inherent low-tribocharging properties without antistatic additives or carbon shedding.
- Homogeneous resistance through the material, not only at the surface.
- 6 mil thickness with consistently low particulate and extractible ion levels.
- Packed in double, vacuum-sealed poly bags.
Specifications and Purchase Unit
| Specification | Detail |
|---|---|
| Manufacturer / SKU | ACL Staticide / GL12NI-S |
| Size | Small |
| Length | 12 inches |
| Material | Nitrile; latex-free |
| Thickness | 6 mil |
| Powder | Powder-free |
| Cleanroom designation | ACL lists ISO 5 / Class 100 cleanroom use |
| Manufacturer recommendation | Suggested for Class II static sensitivity devices |
| Pack quantity | 100 individual gloves |
| Packs per case | 5 |
| Order unit | 1 case = 500 individual gloves |
| Packaging | Double, vacuum-sealed poly bags |
Manufacturer-Reported Electrical Test Data
The values below reproduce ACL's published notation and test conditions. Resistance measurements depend on the test method and conditioning; do not treat them as interchangeable values or a guarantee for every workplace environment.
| Measurement | Published average | Test method / conditioning |
|---|---|---|
| CAFE RGP | 10e9 ohms | ANSI/ESD SP15.1; 50% RH for 48 hours |
| Surface resistance | 10e11 ohms | ANSI/ESD STM11.11; 10% RH for 48 hours |
| Volume resistance | 10e9 ohms | ANSI/ESD STM11.12; 50% RH for 48 hours |
Length and Size Comparison
| Selection | What differs | Selection consideration |
|---|---|---|
| GL12NI-S, this listing | Small; 12-inch length | Small fit with additional wrist coverage |
| GL9NI-S | Small; 9-inch length | Same nominal size with a shorter glove format |
| Other GL12NI sizes | Medium, Large, XL, and 2XL; 12-inch length | Select according to fit while retaining the longer format |
Best-Use Practices
Select a fit that supports dexterity without excessive tightness or loose fingertips. Follow your facility's gowning and glove-change procedures, and replace damaged or contaminated gloves. Evaluate the gloves within your ESD control program rather than using them as a substitute for required grounding. For chemical handling, obtain chemical-specific compatibility and exposure guidance; doubling gloves is not proof of suitability for a particular chemical.
Frequently Asked Questions
How many gloves do I receive?
One ordered case contains 500 individual gloves: five packs with 100 gloves each. This is not a case of 500 pairs.
Is the price for a pack or a case?
The listed price is for one case of 500 gloves, not a single 100-glove pack.
What size and length is GL12NI-S?
GL12NI-S is Small with a 12-inch length. The size and length are specific to this listing.
Are these gloves latex-free and powder-free?
Yes. ACL specifies latex-free nitrile and powder-free construction, manufactured without plasticizers or silicone.
How do these gloves provide antistatic properties?
ACL attributes the performance to nitrile's inherent low-tribocharging nature and homogeneous resistance through the material, without antistatic additives or carbon shedding.
Are they suitable for cleanroom applications?
ACL lists ISO 5 / Class 100 cleanroom use, low particulates and extractible ion levels, and double, vacuum-sealed packaging. Confirm suitability under your facility's qualification procedures.
What is the difference between the 9-inch and 12-inch versions?
The 12-inch format provides additional wrist coverage. This listing is the Small 12-inch version; the Small 9-inch version uses SKU GL9NI-S.
Can they be used with any chemical?
Do not assume universal chemical compatibility. Review chemical-specific glove guidance and your workplace procedures before use.
Technical Datasheet and Related Resources
ACL Staticide ESD Nitrile Gloves Technical Datasheet
Browse the ACL Staticide collection for related static-control products.