ACL Staticide GL12NI-L ESD Nitrile Gloves, Large, 12-Inch, 500 Gloves (5 × 100)
ACL Staticide GL12NI-L ESD Nitrile Gloves, Large, 12-Inch, 500 Gloves (5 × 100)
ACL Staticide GL12NI-L are Large, 12-inch powder-free ESD nitrile gloves for handling sensitive components in electronics manufacturing and controlled environments. The 6 mil nitrile material combines low tribocharging characteristics with resistance through the material, rather than only at the surface. The extended cuff provides more coverage than the 9-inch version.
Quantity per purchase: 500 individual gloves, supplied as five packs of 100 gloves. This is not a single 100-glove pack or 500 pairs. This page is specifically for GL12NI-L, Large, 12-inch gloves; other sizes and lengths retain their own product pages.
At an assembly or inspection station, select the Large size for an appropriate fit, use the extended cuff for additional wrist coverage and replenish from the five individually packed units. ACL manufactures these disposable gloves without powders, silicone or plasticizers to help control handling contamination.
Best Uses / Applications
- ESD-protected areas and handling of static-sensitive components.
- Electronics assembly, inspection and packaging.
- IC and disk-drive manufacturing.
- Controlled critical environments and coordinate-measuring-machine rooms.
- Defense, avionics and automotive electronics production.
- Tasks requiring Large-size fit and an extended 12-inch cuff.
Key Features
- Large size, manufacturer part GL12NI-L.
- 12-inch extended cuff and 6 mil thickness.
- Powder-free nitrile, an alternative to natural-rubber latex.
- Low tribocharging material with homogeneous resistance.
- No added carbon shedding; manufactured without plasticizers, silicone or powder.
- Manufacturer-listed ISO 5 / Class 100 cleanroom suitability.
- Low particulates and extractable ion levels, per ACL.
- Double vacuum-sealed poly-bag packaging.
- 500 gloves per purchase: five packs of 100.
Technical Specifications
| Manufacturer | ACL Staticide |
|---|---|
| Part Number | GL12NI-L |
| Product Family | Staticide ESD Nitrile Gloves |
| Size | Large |
| Length | 12 inches |
| Material | Nitrile |
| Thickness | 6 mil |
| Powder | Powder-free |
| Cleanroom Classification | ISO 5 / Class 100, manufacturer-listed |
| Packaging | Double vacuum-sealed poly bags |
| Pack Quantity | 100 individual gloves |
| Selling Unit | Five packs, 500 individual gloves total |
| Use Type | Disposable |
Manufacturer-Published Electrical Test Data
| Test | Published Average | Method / Conditioning |
|---|---|---|
| CAFE RGP | 10⁹ ohms | ANSI/ESD SP15.1; 50% RH, 48 hours |
| Surface resistance | 10¹¹ ohms | ANSI/ESD STM11.11; 10% RH, 48 hours |
| Volume resistance | 10⁹ ohms | ANSI/ESD STM11.12; 50% RH, 48 hours |
These are ACL's published averages under the stated conditions, not guaranteed readings for every glove or environment. Evaluate glove suitability within your facility's ESD-control and contamination-control procedures. Glove selection alone does not establish compliance of an entire workstation or ESD program.
12-Inch Large vs. Other Options
| Option | Selection Difference |
|---|---|
| GL12NI-L, this listing | Large fit, 12-inch length, five 100-glove packs. |
| 9-inch Large nitrile gloves | Shorter cuff; choose based on coverage needs rather than assuming a different hand size. |
| Other 12-inch sizes | Different hand fit while retaining the longer cuff format; sold on separate pages. |
| Single 100-glove pack | One pack rather than this listing's five-pack, 500-glove selling unit. |
| Standard disposable nitrile gloves | Do not assume equivalent ESD characteristics without the exact manufacturer's electrical data. |
Selection & Handling Notes
Choose fit based on hand dimensions and your workplace requirements; the supplied source does not provide a Large-size hand-width chart. The ISO 5/Class 100 designation is not a statement that the gloves are sterile. Do not treat general chemical-splash wording as a chemical-specific protection rating: select gloves for chemical tasks using appropriate permeation and compatibility data.
Frequently Asked Questions
How many gloves do I receive?
500 individual gloves total, in five packs of 100. The quantity is gloves, not pairs.
Which size and length is GL12NI-L?
Large, with a 12-inch extended cuff. This page does not combine sizes as purchase variants.
Are these gloves powder-free?
Yes. ACL identifies the nitrile formulation as powder-free and manufactured without silicone or plasticizers.
Are these suitable for cleanroom use?
ACL lists ISO 5 / Class 100 cleanroom suitability and double vacuum-sealed poly-bag packaging. Confirm suitability for your specific contamination-control process.
Are the gloves sterile?
The manufacturer page does not establish sterility. Cleanroom classification and sterile status are different attributes.
What makes these ESD nitrile gloves different?
ACL describes inherent low tribocharging characteristics and resistance through the nitrile material. The electrical table provides the published test averages and conditioning details.
Why choose the 12-inch cuff?
It provides greater wrist coverage than the 9-inch version. Choose the length appropriate to your work and garment arrangement.
Can these replace personnel grounding?
Do not assume they replace your prescribed grounding controls. Evaluate glove use within your facility's ESD-control procedures.
Do they provide universal chemical protection?
No universal chemical-protection rating is established here. Verify compatibility and permeation data for the exact substance and task.
Can I buy another size?
Other sizes are separate product listings. This page is specifically GL12NI-L, Large, 12-inch, 500 gloves.
Technical Datasheet
ACL Staticide ESD Nitrile Gloves Technical Datasheet (PDF)