Permabond DD50MLSTATICMIXER03, Static Mixer 50ml For Dispensing, Sulzer Quadro, Square, Case of 25 Permabond MTESolutions

Permabond DD50MLSTATICMIXER03, Static Mixer 50ml For Dispensing, Sulzer Quadro, Square, Case of 25

Permabond SKU: DD50MLSTATICMIXER03
Price
Regular price $125.83
Regular price Sale price $125.83
/
Minimum quantity allowed is .
Maximum quantity allowed is .
The product can be bought in quantity increments of .
Shipping calculated at checkout.

Permabond DD50MLSTATICMIXER03, Static Mixer 50ml For Dispensing, Sulzer Quadro, Square, Case of 25

Permabond DD50MLSTATICMIXER03 is a square static mixing nozzle supplied as a case of 25 for compatible 50 ml two-component dispensing systems. This listing identifies the mixer as Sulzer MBQ05-24L, also written MBQ 05-24L in medmix documentation. Use it only when the cartridge connection and the adhesive manufacturer's required mixer specification match.

Best Uses / Applications

  • Two-component adhesive dispensing where the specified mixer is MBQ 05-24L.
  • Assembly and repair bonding processes using compatible 50 ml cartridge systems.
  • Replacement mixer supply for repeat dispensing tasks, subject to the adhesive's working time and changeover procedure.
  • Purchasing by a defined nozzle reference rather than cartridge volume alone.

Key Features

  • Square QUADRO mixing design for two-component materials.
  • Existing listing cross-reference: Sulzer MBQ05-24L.
  • medmix lists MBQ 05-24L as article 114145 with 24 mixing elements and a Luer outlet.
  • MBQ mixers are documented for compatible B-System 1:1 and 2:1 cartridge configurations; this is not universal compatibility with all cartridges at those ratios.
  • Case quantity: 25 mixers. Adhesive cartridges and dispensing guns are not included in this listing.

Specifications & Selection Details

Item Details
Permabond ordering code DD50MLSTATICMIXER03
Product type Static mixing nozzle for two-component dispensing
Listed cross-reference Sulzer MBQ05-24L / MBQ 05-24L
Mixer geometry Square / QUADRO
Nominal cartridge application Compatible 50 ml systems; connection must be checked
Mixing elements, referenced MBQ 05-24L 24
Outlet, referenced MBQ 05-24L Luer
medmix article reference 114145
System ratio guidance Compatible B-System 1:1 and 2:1 configurations; verify the exact cartridge and adhesive requirements
Quantity sold Case of 25
Compatibility limitation 50 ml volume alone does not confirm fit, adequate mixing, or suitability for a particular adhesive grade

The mixer details above follow the MBQ05-24L reference recorded for this listing and medmix's corresponding documentation. An exact Permabond product page confirming that cross-reference was not located. Confirm the current supplied nozzle reference for a critical process or replacement specification.

Before Choosing a Replacement Mixer

  1. Check the cartridge outlet and mixer attachment, not just its 50 ml capacity.
  2. Confirm the cartridge ratio and compatible mixer system.
  3. Follow the adhesive manufacturer's specified nozzle length and number of mixing elements.
  4. Confirm any required outlet accessory fits the mixer.
  5. Follow the adhesive's purge, working-time, and mixer-replacement instructions.

Square vs. Round Static Mixers

Selection point Square QUADRO mixer Round mixer
Design Square mixing geometry Round mixing geometry
Permabond guidance Quadrant geometry can provide effective mixing in a shorter nozzle for some applications. May also be appropriate when specified for the adhesive and cartridge.
Interchangeability Do not substitute based on shape alone. Match connection, ratio, and the adhesive manufacturer's mixing requirements.

Dispensing Guidance

Permabond's training guidance recommends checking that both cartridge components dispense evenly before attaching the specified mixer, then purging the new nozzle before applying adhesive. Follow the current instructions for the exact adhesive grade rather than treating a general purge amount or working time as universal. Replace the nozzle when required by the material's instructions; do not assume a nozzle containing cured adhesive can be reused.

Frequently Asked Questions

What is DD50MLSTATICMIXER03?

It is the Permabond ordering code for this square static mixer listing, sold as a case of 25. The recorded mixer reference is Sulzer MBQ05-24L.

Does 50 ml describe the amount of adhesive included?

No. It describes the nominal cartridge application for the mixer. This listing is for mixing nozzles, not adhesive cartridges or a dispensing gun.

Will it fit any 50 ml cartridge?

No universal fit is established. Check the cartridge connection, ratio, and adhesive manufacturer's specified mixer. Cartridges with the same volume can require different nozzles.

Can it be used with 1:1 and 2:1 adhesives?

medmix documents MBQ mixers for compatible B-System 1:1 and 2:1 cartridge configurations. That does not establish suitability for every adhesive or every cartridge at those ratios. Confirm the exact cartridge and adhesive grade before use.

How many mixing elements does MBQ 05-24L have?

medmix lists the referenced MBQ 05-24L, article 114145, with 24 elements and a Luer outlet. These specifications apply to that referenced mixer.

Can I replace it with a shorter nozzle?

Only if the adhesive manufacturer approves the replacement. Permabond stresses using the specified nozzle length and number of mixing elements to achieve adequate mixing.

Can I keep using the mixer after the adhesive cures?

Do not assume it is reusable after material cures inside it. Follow the adhesive manufacturer's storage and restart procedure, using a new mixer when required.

Related Products & Resources

Browse the Permabond collection and our Adhesives, Dispensing & UV Cure Systems guide for broader product-selection context.

You may also like
More from Permabond
More from All Products
Recently viewed