Permabond DD50MLSTATICMIXER03, Static Mixer 50ml For Dispensing, Sulzer Quadro, Square, Case of 25
Permabond DD50MLSTATICMIXER03, Static Mixer 50ml For Dispensing, Sulzer Quadro, Square, Case of 25
Permabond DD50MLSTATICMIXER03 is a square static mixing nozzle supplied as a case of 25 for compatible 50 ml two-component dispensing systems. This listing identifies the mixer as Sulzer MBQ05-24L, also written MBQ 05-24L in medmix documentation. Use it only when the cartridge connection and the adhesive manufacturer's required mixer specification match.
Best Uses / Applications
- Two-component adhesive dispensing where the specified mixer is MBQ 05-24L.
- Assembly and repair bonding processes using compatible 50 ml cartridge systems.
- Replacement mixer supply for repeat dispensing tasks, subject to the adhesive's working time and changeover procedure.
- Purchasing by a defined nozzle reference rather than cartridge volume alone.
Key Features
- Square QUADRO mixing design for two-component materials.
- Existing listing cross-reference: Sulzer MBQ05-24L.
- medmix lists MBQ 05-24L as article 114145 with 24 mixing elements and a Luer outlet.
- MBQ mixers are documented for compatible B-System 1:1 and 2:1 cartridge configurations; this is not universal compatibility with all cartridges at those ratios.
- Case quantity: 25 mixers. Adhesive cartridges and dispensing guns are not included in this listing.
Specifications & Selection Details
| Item | Details |
|---|---|
| Permabond ordering code | DD50MLSTATICMIXER03 |
| Product type | Static mixing nozzle for two-component dispensing |
| Listed cross-reference | Sulzer MBQ05-24L / MBQ 05-24L |
| Mixer geometry | Square / QUADRO |
| Nominal cartridge application | Compatible 50 ml systems; connection must be checked |
| Mixing elements, referenced MBQ 05-24L | 24 |
| Outlet, referenced MBQ 05-24L | Luer |
| medmix article reference | 114145 |
| System ratio guidance | Compatible B-System 1:1 and 2:1 configurations; verify the exact cartridge and adhesive requirements |
| Quantity sold | Case of 25 |
| Compatibility limitation | 50 ml volume alone does not confirm fit, adequate mixing, or suitability for a particular adhesive grade |
The mixer details above follow the MBQ05-24L reference recorded for this listing and medmix's corresponding documentation. An exact Permabond product page confirming that cross-reference was not located. Confirm the current supplied nozzle reference for a critical process or replacement specification.
Before Choosing a Replacement Mixer
- Check the cartridge outlet and mixer attachment, not just its 50 ml capacity.
- Confirm the cartridge ratio and compatible mixer system.
- Follow the adhesive manufacturer's specified nozzle length and number of mixing elements.
- Confirm any required outlet accessory fits the mixer.
- Follow the adhesive's purge, working-time, and mixer-replacement instructions.
Square vs. Round Static Mixers
| Selection point | Square QUADRO mixer | Round mixer |
|---|---|---|
| Design | Square mixing geometry | Round mixing geometry |
| Permabond guidance | Quadrant geometry can provide effective mixing in a shorter nozzle for some applications. | May also be appropriate when specified for the adhesive and cartridge. |
| Interchangeability | Do not substitute based on shape alone. Match connection, ratio, and the adhesive manufacturer's mixing requirements. | |
Dispensing Guidance
Permabond's training guidance recommends checking that both cartridge components dispense evenly before attaching the specified mixer, then purging the new nozzle before applying adhesive. Follow the current instructions for the exact adhesive grade rather than treating a general purge amount or working time as universal. Replace the nozzle when required by the material's instructions; do not assume a nozzle containing cured adhesive can be reused.
Frequently Asked Questions
What is DD50MLSTATICMIXER03?
It is the Permabond ordering code for this square static mixer listing, sold as a case of 25. The recorded mixer reference is Sulzer MBQ05-24L.
Does 50 ml describe the amount of adhesive included?
No. It describes the nominal cartridge application for the mixer. This listing is for mixing nozzles, not adhesive cartridges or a dispensing gun.
Will it fit any 50 ml cartridge?
No universal fit is established. Check the cartridge connection, ratio, and adhesive manufacturer's specified mixer. Cartridges with the same volume can require different nozzles.
Can it be used with 1:1 and 2:1 adhesives?
medmix documents MBQ mixers for compatible B-System 1:1 and 2:1 cartridge configurations. That does not establish suitability for every adhesive or every cartridge at those ratios. Confirm the exact cartridge and adhesive grade before use.
How many mixing elements does MBQ 05-24L have?
medmix lists the referenced MBQ 05-24L, article 114145, with 24 elements and a Luer outlet. These specifications apply to that referenced mixer.
Can I replace it with a shorter nozzle?
Only if the adhesive manufacturer approves the replacement. Permabond stresses using the specified nozzle length and number of mixing elements to achieve adequate mixing.
Can I keep using the mixer after the adhesive cures?
Do not assume it is reusable after material cures inside it. Follow the adhesive manufacturer's storage and restart procedure, using a new mixer when required.
Related Products & Resources
Browse the Permabond collection and our Adhesives, Dispensing & UV Cure Systems guide for broader product-selection context.