Transforming Technologies Bench Top Ionizer Transforming Technologies MTESolutions

Transforming Technologies IN5110 Bench Top Ionizer

Transforming Technologies SKU: IN5110
Price
Regular price $696.47
Regular price Sale price $696.47
/
Minimum quantity allowed is .
Maximum quantity allowed is .
The product can be bought in quantity increments of .
Shipping calculated at checkout.

Transforming Technologies IN5110 Bench Top Ionizer

Transforming Technologies IN5110 is a Ptec benchtop ionizing blower for neutralizing electrostatic charge in personal work areas and sensitive-material assembly processes. Its piezoceramic high-voltage technology produces high-frequency 68 kHz AC ion emission, while variable fan speed allows airflow to be adjusted for the application.

The IN5110 complements appropriate grounding by addressing charge on materials that cannot be grounded by ordinary means. It does not replace personnel grounding or establish that an entire workstation is controlled simply because the fan is running. Evaluate performance at the actual handling location with the normal parts, fixtures and obstructions in place.

Best Uses / Applications

  • Electronics assembly and SMT: evaluate charge neutralization around process-essential insulating materials in the work area.
  • Inspection and laboratory benches: direct ionized airflow toward the relevant handling location, then verify performance using an appropriate method.
  • Sensitive-material assembly: use the compact blower where local benchtop placement fits the workflow.
  • Packaging operations: assess charge on process materials that cannot be grounded, alongside appropriate packaging and grounding controls.
  • Controlled manufacturing environments: the manufacturer lists cleanroom applications, but suitability for a particular cleanliness classification and process must be established separately.

Key Features

  • Ptec piezoceramic ionization technology.
  • High-frequency AC ion emission at 68 kHz.
  • Variable-speed fan and adjustable bracket/stand.
  • Manufacturer-reported decay from 1,000 V to 100 V in less than 2 seconds at 12 inches under its test conditions.
  • High-voltage failure alarm indication and relay.
  • Quick-release removable fan grilles for maintenance access.
  • Tungsten-alloy emitter points and a replaceable filter.
  • Manufacturer describes the technology as not requiring calibration; performance verification and maintenance remain separate responsibilities.

Technical Specifications

Manufacturer / model Transforming Technologies / IN5110
Technology Ptec piezoceramic benchtop ionization
Ion emission AC, 68 kHz
Power input 24 VDC, 12 W
Decay time 1,000 V to 100 V in less than 2 seconds at 12 in, manufacturer test data
Airflow 115 cfm at high speed
Noise level 60 dB(A) at 1 m
Operating temperature listed in data sheet 19–25°C / 66–78°F
Humidity 20–60% RH, non-condensing
Controls On/off switch and variable fan speed
Indicators Green operating indicator and red high-voltage alarm indicator
Mounting Adjustable bracket/stand
Emitter points Tungsten alloy
Filter Replaceable
Unit dimensions in data sheet 7.5 in H × 7.1 in W × 2.7 in D
Unit weight including stand 2.8 lb / 1.27 kg
Manufacturer warranty listing 1-year limited warranty; confirm current terms with manufacturer

Performance figures are manufacturer data, not a guarantee at every workstation location. Verify the actual setup, source distance and process conditions. The manufacturer page and supplied PDF differ in their balance figures, so obtain the current balance specification from Transforming Technologies before using a numerical value as an acceptance criterion.

Placement, Maintenance and Verification

Position the ionizer so its airflow reaches the relevant handling area without being obstructed by fixtures, containers or equipment. A single decay-time figure measured at 12 inches does not establish uniform performance across an entire bench.

Use current manufacturer instructions for emitter maintenance, filter replacement and safe access. Quick-release grilles simplify access, but do not remove the need to follow electrical-safety and maintenance directions. Set service frequency using the environment, manufacturer guidance and performance history rather than an unsupported fixed interval.

The high-voltage alarm signals a detected failure condition; it is not a complete ion-balance or discharge-time measurement. Verify those performance characteristics using suitable test equipment and the procedure defined for the process. A product data-sheet test reference does not by itself establish compliance of your complete workstation.

Selection Comparison

Requirement IN5110 selection guidance
Local benchtop ionization Evaluate the adjustable stand, available bench space and airflow path at the actual handling position.
Keeping the bench clear or covering a larger area Compare an appropriate overhead configuration and verify performance at all required locations; do not assume a broader area is covered without testing.
Monitoring operator and mat grounding Use a suitable monitor, such as the CM410, for its separate monitoring role. An ionizer does not perform that function.
Testing ionizer performance Select appropriate ionizer test equipment separately. Neither a running fan nor a green operating light proves performance at the workpiece.
A specific cleanroom class Confirm suitability and documentation for the actual process. A listed cleanroom application is not universal classification approval.

Frequently Asked Questions

What is the SKU for this benchtop ionizer?

The product model and SKU are IN5110. This listing is for the Transforming Technologies Ptec benchtop ionizing blower.

Is this an AC or DC ionizer?

The ion-emission technology is high-frequency AC at 68 kHz. Its electrical power input is specified separately as 24 VDC, 12 W. Do not confuse the input supply with the ion-emission technology.

How fast does it neutralize charge?

The supplied sheet reports decay from 1,000 V to 100 V in less than 2 seconds at 12 inches under the manufacturer's test conditions. Distance, airflow, obstructions and the actual work arrangement affect results.

Does it replace wrist straps and ESD mats?

No. Ionization and grounding have different roles. Maintain the appropriate grounding controls and assess ionization for materials that cannot be grounded by ordinary means.

Does the high-voltage alarm verify ion balance?

No. A failure alarm is not the same as measuring balance and decay performance at the handling location. Use suitable test equipment and an approved verification method.

How often should the emitters be cleaned?

Follow the current manufacturer instructions and adjust maintenance using environmental conditions and verified performance history. The supplied sheet describes maintenance access but does not establish a universal 3–6-month cleaning interval.

Is it approved for every cleanroom?

No such blanket claim is established by the supplied sheet. The manufacturer lists cleanroom applications, but suitability for a particular classification, materials and procedure requires separate evaluation.

Manufacturer Data Sheet

Download the Transforming Technologies IN5110 Ptec data sheet (PDF) for manufacturer specifications and decay-performance information.

Related Resources

Compare ionization products and ESD workstation accessories. Read How to Design an Effective ESD Workstation for the wider selection framework, including the distinct roles of grounding, monitoring and ionization.

Recently viewed