ACL Staticide 4800-2 Ultra II Floor Finish, 54-gallon drum ACL Staticide MTESolutions

ACL Staticide 4800-2 Ultra II ESD Dissipative Floor Finish, 54-Gallon Drum

ACL Staticide SKU: 4800-2
Price
Regular price $3,883.33
Regular price Sale price $3,883.33
/
Minimum quantity allowed is .
Maximum quantity allowed is .
The product can be bought in quantity increments of .
Shipping calculated at checkout.

ACL Staticide 4800-2 Ultra II ESD Dissipative Floor Finish, 54-Gallon Drum

ACL Staticide 4800-2 Ultra II is a urethane-enhanced acrylic floor finish for specialty flooring and static-control maintenance. The 54-gallon drum provides bulk supply for large facilities and high-volume floor-care programs. Its advanced acrylic polymer provides adhesion on concrete, epoxy, ESD epoxy and dissipative tile, including specialty flooring with problematic plasticizers, while leaving a glossy, abrasion-resistant finish.

Best Uses / Applications

  • Large electronics manufacturing areas with installed ESD flooring.
  • High-volume maintenance programs across multiple approved flooring areas.
  • Maintaining out-of-warranty ESD tile after evaluating floor condition and compatibility.
  • Concrete, epoxy, ESD epoxy and dissipative tile maintenance.
  • Medical facilities and cleanrooms where approved by facility procedures.

Key Features

  • 54-gallon bulk drum for large-volume floor-care needs.
  • Urethane-enhanced acrylic formulation for durability and abrasion resistance.
  • Compatible with problematic plasticizers in conductive or dissipative tile and epoxy.
  • Glossy finish that resists yellowing, flaking and scuffing.
  • UL-listed for slip resistance.
  • Manufacturer states compliance with ANSI/ESD S20.20; verify installed floor performance within your ESD program.
  • Free of formaldehyde, phthalates, alkalis and acids. This does not mean hazard-free; consult the SDS.

Technical Specifications

Specification Detail
Manufacturer / SKU ACL Staticide / 4800-2
Product 4800 Ultra II Dissipative Floor Finish
Package 54-gallon drum
Formula Urethane-enhanced acrylic polymer
Surface resistance, RTT 10⁷–10⁹ ohms at 100 V and 12% RH
Coverage Approximately 750–1,000 sq. ft. per gallon for two coats
Estimated drum coverage Approximately 40,500–54,000 sq. ft. for two coats, calculated from published per-gallon coverage; actual results depend on substrate and application
Solids 21% ±5%
VOC Less than 4%
Slip resistance UL listed
Manufacturer-stated compliance ANSI/ESD S20.20
Published strip cycle 12–18 months; assess maintenance needs for actual conditions
Surfaces Concrete, epoxy, ESD epoxy and dissipative tile

Best-Use Practices

  • Review the application manual, TDS and SDS before preparing or coating the floor.
  • Confirm compatibility with the floor manufacturer and evaluate a small area before broad application.
  • Follow ACL instructions for preparation, coating, drying and maintenance; do not substitute assumed cure times.
  • Keep personnel off the treated area until it is ready for use under the application instructions.
  • Measure installed floor resistance and validate personnel-grounding performance as required by your ESD program. A finish alone does not certify the facility.
  • Use facility-approved maintenance procedures and reassess performance as the finish wears.
  • Plan bulk deliveries around ACL's freeze-sensitive winter shipping restrictions.

Ultra II Package Comparison

SKU Package Selection consideration
4800-1 1-gallon containers, 4 per case Separate containers for distributed maintenance
4800-5 5-gallon pail Larger floor-care projects
4800-2, this listing 54-gallon drum Bulk facility maintenance

Frequently Asked Questions

What package does 4800-2 include?

This listing is for a 54-gallon drum of Staticide 4800 Ultra II dissipative floor finish, not a 55-gallon fill.

Is the formula the same as the smaller packages?

Yes. 4800-1, 4800-5 and 4800-2 are package options for Staticide 4800 Ultra II. Choose the quantity and container format suited to your maintenance program.

How much area can the drum cover?

Published coverage is approximately 750–1,000 sq. ft. per gallon for two coats. Fifty-four gallons gives an estimated 40,500–54,000 sq. ft., depending on substrate and application conditions.

Which floors can it be used on?

ACL lists concrete, epoxy, ESD epoxy and dissipative tile. Confirm compatibility with your flooring and follow preparation instructions.

What is its electrical resistance?

ACL reports surface resistance, RTT, of 10⁷–10⁹ ohms at 100 V and 12% relative humidity. Verify performance on the installed floor.

Does it certify the facility to ANSI/ESD S20.20?

No. ACL states product compliance; facility compliance depends on the complete ESD control program, installed flooring, grounding and verification procedures.

Is it slip-resistant?

ACL lists Ultra II as UL-listed for slip resistance. Follow application and maintenance instructions; the listing does not eliminate all slip risks.

How often should it be stripped?

ACL publishes a 12–18 month strip cycle. Determine actual maintenance timing from traffic, condition and measured performance rather than treating this as a guaranteed service life.

Is it hazard-free or approved for every cleanroom?

No. Although free of formaldehyde, phthalates, alkalis and acids, it still requires SDS-based handling precautions. Cleanroom acceptance depends on facility requirements; no specific ISO class is established here.

Are there winter shipping restrictions?

ACL warns of extended winter lead times due to limited freeze cycles. The manufacturer ships floor finishes and paint on Mondays and Tuesdays during winter and may halt shipments during extreme weather.

Technical and Safety Documents

Technical Data Sheet | Safety Data Sheet | Application Manual

Related ESD Resources

Review ESD Program Essentials for program planning and browse the ACL Staticide collection for related static-control products.

Recently viewed