Lakeland CleanMax Sterile Boot Cover, CTL903CSP, 50 Pair/ Case Lakeland MTESolutions

Lakeland CleanMax Sterile Boot Cover, CTL903CSP, 50 Pair/ Case

Lakeland SKU: CTL903CSP-SMMD
Size
Price
Regular price $382.27
Regular price Sale price $382.27
/
Minimum quantity allowed is .
Maximum quantity allowed is .
The product can be bought in quantity increments of .
Shipping calculated at checkout.

Lakeland CleanMax Sterile Boot Cover, CTL903CSP, 50 Pair/ Case

Lakeland CleanMax CTL903CSP boot covers are clean-manufactured sterile garments with a 19-inch length and elastic top. Lakeland identifies them as compatible with ISO Class 4–8 cleanrooms and controlled environments, with IEST-RP-CC003 Category I particle cleanliness. Open-fold presentation and individually packed pairs with a protective outer bag support facility-controlled donning in ante areas.

Supplied as 50 individually packed pairs per case. Select and qualify footwear coverage within your facility's complete gowning program.

Best Uses / Applications

  • Sterile cleanroom gowning programs requiring clean-manufactured boot covers.
  • Pharmaceutical and medical-device controlled environments where the facility approves this garment.
  • ISO Class 4–8 cleanrooms needing documented particle-cleanliness guidance.
  • Ante-area gowning workflows using individually packed pairs and protective outer bags.
  • Facilities specifying latex- and silicone-free cleanroom apparel.

Key Features

  • Clean-manufactured sterile boot-cover configuration.
  • 19-inch length and elastic top.
  • Manufacturer states clean manufacture in a silicone-free environment.
  • Latex- and silicone-free apparel, per Lakeland.
  • Open-fold presentation for easier donning.
  • Individually packed pairs, with protective outer bag for ante areas.
  • Manufacturer-described fluid repellency and barrier test data, subject to test conditions and facility assessment.

Specifications

Manufacturer / Series Lakeland / CleanMax
Part Number CTL903CSP
Garment Sterile boot cover
Length 19 inches
Top Elastic
Sterilization Irradiation sterilization, as identified on the manufacturer sheet
Cleanroom Compatibility Manufacturer states ISO Class 4–8 and controlled-environment compatibility; facility qualification remains required
Particle Cleanliness IEST-RP-CC003 Category I, per manufacturer
Material Statements Latex and silicone free; clean-manufactured in a silicone-free environment
Presentation Open fold
Packaging 50 individually packed pairs per case; protective outer bag for ante areas

Manufacturer Barrier Test Reference

The linked CTL903CSP sheet provides CleanMax apparel test data. These laboratory results are not a guarantee against every exposure and do not establish protection for an entire gowning ensemble.

Test Reported Result
Synthetic blood penetration, ASTM F1670 Pass; reported penetration time greater than 60 minutes
Viral penetration, ASTM F1671 Pass; reported penetration time greater than 60 minutes
Synthetic blood, ISO 16603 No strikethrough at 20kPa
Blood-borne pathogen penetration, ISO 16604 No strikethrough at 20kPa
Chemotherapy permeation, ASTM D6978 Pass for listed tested drugs; minimum breakthrough time greater than 240 minutes

For drug handling, biological exposure or other hazardous tasks, review the full sheet, exact tested substances, current manufacturer documentation and your facility's risk assessment. Do not treat the chemotherapy result as universal chemical resistance.

Selection Comparison

Requirement CTL903CSP What to Check
Sterile presentation Clean-manufactured sterile; irradiation identified Package integrity, lot documentation and facility acceptance
Cleanroom use ISO Class 4–8 compatibility stated Your gowning and contamination-control requirements
Footwear coverage 19-inch length; elastic top Fit over the actual footwear and interface with garments
Slip-risk conditions Sole material is not specified in the extracted product-sheet text Confirm sole construction and suitability before selection

Frequently Asked Questions

How many pairs come in a case?

Lakeland lists 50 individually packed pairs per case, rather than 50 individual boot covers.

How tall are the boot covers?

The manufacturer sheet identifies a 19-inch length and elastic top. Confirm fit over your footwear and the required gowning overlap.

Are CTL903CSP boot covers sterile?

Yes. The product-specific sheet identifies clean-manufactured sterile boot covers and irradiation sterilization. Follow package labeling, inspect package integrity and use your facility's approved procedures.

Which cleanroom classes are they compatible with?

Lakeland states compatibility with ISO Class 4–8 cleanrooms and controlled environments. This is garment compatibility guidance, not certification of your facility or gowning process.

What particle-cleanliness guidance is supplied?

The manufacturer identifies IEST-RP-CC003 Category I particle cleanliness. Your quality team should review the documentation against your process requirements.

Are they latex and silicone free?

Lakeland states its CleanMax apparel is latex and silicone free and identifies clean manufacture in a silicone-free environment.

Do the chemotherapy tests cover every drug or chemical?

No. The sheet reports ASTM D6978 results for listed tested drugs. Check the exact substances and conditions before selection; do not infer universal chemical protection.

Does barrier testing guarantee protection in use?

No. Laboratory test results do not remove the need for proper selection, intact garments, approved donning, compatible ensemble components and a task-specific safety assessment.

Can these be used around heat or flames?

Lakeland warns that cleanroom apparel should not be used around heat, flames or sparks, or in potentially flammable or explosive environments. Follow that warning and confirm slip-resistant footwear coverage where needed.