Transforming Technologies IN4200 Airflex Ionizer, Mountable
Transforming Technologies IN4200 Airflex Ionizer, Mountable
The Transforming Technologies IN4200 Airflex mountable ionizer is a flexible-neck, compressed-gas ionizing nozzle for precision static neutralization. Its footswitch controls the static-eliminating airflow, leaving both hands free for handling parts. The flexible neck directs ionized air toward hard-to-reach work areas where larger ionizers may not fit.
Best Uses / Applications
- Localized ionization at electronics assembly and SMT workstations.
- Sensitive-material assembly where a flexible nozzle can reach the handling area.
- Packaging and laboratory tasks requiring directed airflow and hands-free activation.
- Cleanroom applications after separate assessment of filtration and process suitability.
Key Features
- Mountable flexible-neck design for targeted airflow.
- Ptec piezoceramic technology produces high-frequency 68 kHz AC ions.
- Foot-operated switch activates ionization when required.
- Optional nozzle tips offer wide-angle, manifold, long-range, angled or extension configurations.
- Optional replaceable 0.01-micron filter; the datasheet also permits operation without a filter.
- Green ionization indicator and red high-voltage alarm indicator.
- Manufacturer states no calibration or periodic adjustment is required; maintenance and performance verification are still necessary.
Technical Specifications
| Specification | Manufacturer data |
|---|---|
| Model / SKU | IN4200 |
| Brand | Transforming Technologies |
| Type | Airflex mountable flexible-neck ionizing nozzle |
| Power input | 100–240 VAC, 50/60 Hz |
| Ion emission | AC, 68 kHz |
| Balance | +30 volts, as printed in the datasheet |
| Typical decay time | 1,000 V to 100 V in less than 2 seconds at 12 in |
| Gas supply | Clean dry air (CDA) or nitrogen (Nâ‚‚) |
| Pressure discrepancy | Air Pressure row lists 10–100 psi; Gas Input & Connection row lists 20–75 psi. Confirm the applicable operating range with the manufacturer before setup. |
| Gas connection | 1/4 in male industrial-interchange quick disconnect or 1/4 in quick-release tube fitting, per datasheet |
| Controls | Footswitch |
| Mounting | Table mount, per datasheet; confirm hardware for the intended installation |
| Indicators | Green power/ionization; red alarm |
| Emitter points | Tungsten alloy |
| Temperature | 66–78°F (19–25°C) |
| Humidity | 20–60% RH, non-condensing |
| Dimensions | 12 in H × 5.75 in W × 7.25 in D, as listed in the supplied sheet |
| Unit weight | 2.8 lb (1.27 kg), including stand, as listed in the sheet; not a packed shipping weight |
| Filter option | Replaceable 0.01-micron filter |
| Warranty | 1-year limited manufacturer warranty |
The supplied datasheet is revision 2019-10-14. It describes typical offset-voltage and discharge-time testing per ANSI/ESD STM3.1 using a 20 pF, 6 × 6 in charged plate. That test reference does not establish compliance of an entire workstation. Verify performance at the actual work location and confirm current installation requirements.
Selection Comparison
| Consideration | IN4200 mountable nozzle | Benchtop fan ionizer |
|---|---|---|
| Air source | External CDA or nitrogen | Built-in fan |
| Positioning | Flexible neck for localized, hard-to-reach areas | Blower positioned toward the work area |
| Activation | Footswitch for hands-free operation | Model-specific fan and power controls |
| Selection priority | Directed point-of-use airflow | Fan-driven coverage without a compressed-gas connection |
Frequently Asked Questions
What is the model number?
This mountable Airflex listing is SKU IN4200.
Does it operate continuously?
The manufacturer describes footswitch-controlled airflow for hands-free ionization when needed. Select the control arrangement for your process rather than assuming this model is a continuously running blower.
Does the IN4200 require compressed gas?
Yes. It uses clean dry air or nitrogen. The supplied sheet lists conflicting pressure ranges of 10–100 psi and 20–75 psi; confirm the applicable range with Transforming Technologies before installation.
Are the filter and different nozzle tips included?
The manufacturer describes the 0.01-micron filter and alternative nozzle tips as options. Confirm the supplied configuration and order the accessories required for the application.
Does Ptec technology eliminate maintenance?
No. The manufacturer states that calibration is not required and maintenance demands are reduced. Follow current service instructions and verify balance and decay performance at the actual handling position.
Can it replace ESD grounding?
No. Ionization addresses charge on materials that cannot be effectively grounded. It complements appropriate personnel and workstation grounding rather than replacing them.
Manufacturer Data Sheet
Download the IN4200 Airflex datasheet (PDF)
Related Products & Resources
Browse ESD ionization equipment | Shop Transforming Technologies | ESD Program Essentials